Three energy saving functions of the hottest steam

2022-08-08
  • Detail

Three energy-saving functions of steam traps

there are many types of steam traps at present, but their working principle is to use the difference between the height, temperature and flow rate of steam and condensate to realize the opening and closing of steam traps through various mechanisms, so as to achieve the purpose of steam blocking and drainage. It has three main energy-saving effects

provide customers and consumers with excellent products

first, quickly discharge the condensed water generated in the steam using equipment, so as to maintain the heating efficiency of the steam using equipment at the best state, so that the condensed water in the equipment does not form retention, and maximize the energy dissipated in the steam space in the equipment, so as to often maintain the highest heating efficiency. Once the steam trap can not fully play its role, due to the retention of condensate, not only the performance of steam equipment will be greatly affected, sometimes even the production equipment will be completely paralyzed

second, quickly discharge the air and low-temperature condensate in the equipment at the beginning of startup, so as to shorten the preheating operation time. When the steam is started, the steam transmission pipeline and steam using equipment are filled with air. If they are not eliminated, the steam cannot be sent. In addition, in the process of heating the steam transmission pipeline and steam using equipment to reach the steam temperature, the initial low-temperature condensate produced should also be quickly discharged, so that the equipment can realize normal operation in a short time, which is an important condition to improve production efficiency, especially in the case of intermittent production, because the preheating time is shortened, the operation time of each time is shortened, and because the treatment times are increased, the output can be finally increased. In the past, during preheating operation, the bypass valve was first opened to discharge the initial air and low-temperature condensate. Now, due to the selection of appropriate steam traps, the initial air and low-temperature condensate can be discharged automatically, and manpower can be saved

Strive to use 3 to 5 years

third, reduce the steam consumption of the steam trap itself. The so-called steam consumption of the steam trap itself generally refers to the steam leakage, which is the sum of the steam volume and heat loss required by the steam trap action

and the acceptance of waste foamed plastics is gradually expanding

Copyright © 2011 JIN SHI